Flow loop designer.

Draw the route and set the flows, size the equipment, then run a bench experiment.

Pipe length52.1 m
Friction + fittings15.75 kPa
Calculated outlet2.682 bar(a)
Sensor stations2

Route editor

-5051015202530354045505560-50510Z (m)X (m)Section 1 · 8.00 mSection 2 · 8.06 mSection 3 · 8.00 mSection 4 · 8.60 mSection 5 · 9.00 mSection 6 · 10.44 mSection 1INLETOUTLETS1S2
Select a section to name it. Drag points or tags to move them, or double-click a pipe to insert a waypoint.

Pressure profile

Absolute pressure · bar(a)
Absolute pressure (bar abs)2.5582.8033.0470 m52.1 m
Equipment sizing, section results and calculation methods

Equipment duty

Open line · feed equipment supplies the first waypoint.

Liquid pump

20.43 m of liquid head

Pump head expresses the energy added per unit weight of liquid. The pressure increase is 2 bar.

1 → 3 bar(a) · 2 bar pump rise

8 m³/h delivered · 0.635 kW shaft power

Compare centrifugal pump curves at this flow and head.

Gas compressor

3.65 : 1

5 actual m³/h at suction · 1 bar(a) suction

Downstream line at 3 bar(a). To charge the gas buffer, specify 3.65 bar(a) discharge.

Gas buffer

83 L

Buffer volume for a full interruption of gas supply.

Low setpoint 3.15 bar(a) · high 3.65 bar(a). Recharge duty requires a pressure ratio of at least 3.65 : 1.

Machinery shortlist

Liquid pumps

8 m³/h at 20.43 m of liquid head · 2 bar rise

Clean-water curves at 60 Hz. Available head is interpolated at design flow. Screening allows up to 50% excess head. Confirm NPSH, casing pressure and the operating point with the supplier.

Gas compressors

5 actual m³/h at suction · gas buffer charge 3.65 bar(a)

Atmospheric air intake. Each comparison uses delivered air and pressure at the same catalogue point. Confirm inlet conditions, unloading control and recharge duty.

Gas buffer sizes

83 L minimum · 30 s hold-up

  • Kaeser 90 L ↗32.5 s at design demandVertical air receiver · 11 bar(g) rating
  • Kaeser 150 L ↗54.2 s at design demandVertical air receiver · 11 bar(g) rating
Isothermal gas storage during loss of supply. Verify regulator differential, vessel design temperature, relief protection and applicable vessel code.

Segment worksheet

LegDeveloped length (m)Downstream bendR / DRoughness (mm)Inlet bar(a)Outlet bar(a)ΔP (kPa)
Section 1 · W1 → W2829.7° · nominal K—0.04632.97572.429
Section 2 · W2 → W38.06229.7° · nominal K—0.0462.97572.630634.515
Section 3 · W3 → W4835.5° · nominal K—0.0462.63062.60552.507
Section 4 · W4 → W58.60235.5° · nominal K—0.0462.60552.9792-37.368
Section 5 · W5 → W6916.7° · nominal K—0.0462.97922.95262.661
Section 6 · W6 → W710.44Straight—0.0462.95262.681727.081

Station schedule

StationInstrumentDistanceElevationPressure
S1Epsilon · ring4.4 m1 m2.987 bar(a)
S2Sigma · ring pair38.24 m0 m2.963 bar(a)

Pressure balance

Wall friction
15.095 kPa
Bends and fittings
0.656 kPa
Elevation
16.074 kPa
Inlet minus outlet
31.825 kPa

How the calculation works

Line pressure

Pout = Pin − ΔPwall − ΔPfittings − ΔPelevation

Starting at W1, pressure is integrated along the route. Return pressure sets the suction condition for recirculation. This route goes from 3 to 2.6817 bar(a).

Pump duty

H = ΔPpump / (ρL g) · Pshaft = QL ΔPpump / η

The pump supplies the positive pressure rise from suction to W1. 2 bar at 8 m³/h gives 20.43 m head and 0.635 kW shaft power.

Gas supply and buffer

PR = max(1, Phigh / Psuction) · V = ṁ Δt / (ρhigh − ρlow)

The gas buffer cycles between the inlet pressure plus regulator allowance and that value plus the usable swing. Use absolute pressures for the compressor ratio. Volume scales with gas demand and hold time, and depends on the density change across the usable pressure band.

Equations, assumptions and references

SI units are used internally. One bar is 100,000 Pa. Head uses liquid density and g = 9.80665 m/s². Suction and discharge pressures are at equipment connections; feed-line losses and velocity-head differences outside the drawn route are excluded.

Wall friction is f (L/D) ρv²/2, fittings contribute K ρv²/2, and elevation contributes ρg Δz. The solver evaluates fluid properties at segment midpoint pressure and applies fitting losses at the downstream end.

The route length uses X, Y and Z in metres. Darcy–Weisbach friction uses 64/Re for laminar flow and Haaland for turbulent flow, with interpolation from Re 2,300 to 4,000. Rounded turns use tangent circular arcs and a Rennels–Hudson excess loss dependent on R/D, angle and local Darcy factor. The arc contributes wall friction once. Each leg extends between bend midpoints, and the curvature loss is applied at the downstream bend midpoint. Unrounded turns retain the entered nominal K scaled by angle. Additional fitting K is applied at the downstream end of each leg. Elevation contributes a signed hydrostatic term.

Gas density is updated at each local absolute pressure and the operating temperature using the selected equation of state. Peng–Robinson uses a pseudo-pure representation for dry air and checks the stable gas branch for pure gases. Reference liquid properties and gas viscosity are editable. The gas–liquid screening model assumes homogeneous no-slip flow and volume-weighted viscosity. Slugging, phase slip, acceleration losses, heat transfer, detailed phase equilibrium and surge require a separate analysis. For mixed loops the pump and compressor duties assume separate phase feeds at a common mixing pressure.

The receiver is an isothermal mass balance at line temperature. Set the regulator differential allowance from its flow curve and account for feed losses in final sizing. Equipment selection also requires a manufacturer curve, pump NPSH, compressor operating envelope and vessel pressure rating. Fluid presets are illustrative values at about 20 °C. Enter properties at the operating condition.

Hydraulic Institute · System curves ↗ ASHRAE · Pipe design ↗ Two-phase pressure-drop models ↗ Rounded bend correlation ↗ US DOE · Receiver sizing ↗ NIST · Peng–Robinson ↗ CoolProp · Fluid constants ↗